XW1000 sensing cables detect the presence of water at any point along their length. Installed with a alarm and locating module, the cable senses water intrusion, triggers an alarm,
XW1000 sensing cables detect the presence of water at any point along their length.
Installed with a alarm and locating module,
the cable senses water intrusion, triggers an alarm, and pinpoints
the location.
Distributed
sensing
XW1000
sensing cables provide distributed leak detection and location over a wide
range of areas. The cable is available in a variety of lengths
to provide as much coverage as needed.
Design flexibility
XW1000
sensing cable is supplied with factory-installed plastic connectors that plug together.
The cable is designed for a range of applications,
including data center subfloors,
telecommunication rooms, HVAC equipment
locations, pipes, electrical vaults, storage areas, tanks, and roofs. The cable is small, lightweight, and flexible, allowing easy
installation. The smooth design allows for quick drying.
Advanced
technology
The conductive-polymer technology and fluoropolymer construction make XW1000
sensing cable mechanically strong and resistant to
corrosion and abrasion.
The cable is constructed of two sensing wires, an alarm signal
wire, and a continuity wire embedded in a
fluoropolymer carrier
rod. The alarm module constantly
monitors the sensing cable for continuity. The rugged cable construction
exposes no metal, and enables the cable to be reused even
in corrosive environments.
Working Principle
When there is water contact, the two sensing wires will be short
circuited, resulting in the change of current. According to the proportional
relationship between the resistance and the length of the conductor, through
the rapid processing of the controller, the specific leakage location can be
provided
Cable parameter
Cable Characteristics
Cable
diameter 6.0 mm nominal
Continuity
and signal wires 2 x 26 AWG with insulation of fluoropolymer
Sensing
wires 2 x 30 AWG with jacket of
conductive fluoropolymer
Carrier Fluoropolymer
Cable
weight(50 ft/15 m length) 0.5kg
Cable
color High-visibility yellow or brown
Technical
Information
Abrasion
resistance >65 cycles per UL 719
Maximum
continuous operating temperature 75°C
Fire
resistance Class 2 plenum cable per NEC 1996
725-71 (a)
UL
910 Modified Steiner Tunnel Test
Breaking
strength Cable only: 90 kg
Induction line in the laying process to avoid contact with metal objects
Induction line in the process of laying keep dry and clean
Induction line in the docking process, please pay attention to male female connector pins order, alignment hole location and gently insert lock screw clockwise loops (counterclockwise)
Sensor cable laying area should be avoided by electrostatic interference
Induction line in laying area are not allowed to overlap or contact
Sensing line shall not be dirty water or other chemicals soak for a long time
Induction line should be close to the ground installation, the maximum contact leakage of liquid
Online message
在线留言
*Name(Please fill your name)
*Telephone(Please fill your phone number)
Email
*Purchase intention(Please fillproduct quantity and product description)