XW1000 sensing cables

XW1000 sensing cables detect the presence of water at any point along their length. Installed with a alarm and locating module, the cable senses water intrusion, triggers an alarm,

contact
  • Detail
  • Parameter

XW1000 sensing cables detect the presence of water at any point along their length. Installed with a alarm and locating module, the cable senses water intrusion, triggers an alarm, and pinpoints the location.

 

Distributed sensing

XW1000 sensing cables provide distributed leak detection and location over a wide range of areas. The cable is available in a variety of lengths to provide as much coverage as needed.

 

Design flexibility

XW1000 sensing cable is supplied with factory-installed plastic connectors that plug together. The cable is designed for a range of applications, including data center subfloors, telecommunication rooms, HVAC equipment locations, pipes, electrical vaults, storage areas, tanks, and roofs. The cable is small, lightweight, and flexible, allowing easy installation. The smooth design allows for quick drying.

 

Advanced technology

The conductive-polymer technology and fluoropolymer construction make XW1000 sensing cable mechanically strong and resistant to corrosion and abrasion. The cable is constructed of two sensing wires, an alarm signal wire, and a continuity wire embedded in a fluoropolymer carrier rod. The alarm module constantly monitors the sensing cable for continuity. The rugged cable construction exposes no metal, and enables the cable to be reused even in corrosive environments.

Working Principle

When there is water contact, the two sensing wires will be short circuited, resulting in the change of current. According to the proportional relationship between the resistance and the length of the conductor, through the rapid processing of the controller, the specific leakage location can be provided

Cable parameter  

Cable Characteristics

Cable diameter                             6.0 mm nominal

Continuity and signal wires                   2 x 26 AWG with insulation of fluoropolymer

Sensing wires                              2 x 30 AWG with jacket of conductive fluoropolymer

Carrier                                     Fluoropolymer

Cable weight(50 ft/15 m length)            0.5kg

Cable color                                High-visibility yellow or brown

 

Technical Information

Abrasion resistance                          >65 cycles per UL 719

Maximum continuous operating temperature     75°C

Fire resistance                              Class 2 plenum cable per NEC 1996 725-71 (a)

UL 910 Modified Steiner Tunnel Test

Breaking strength Cable only:                90 kg



  • Induction line in the laying process to avoid contact with metal objects
  • Induction line in the process of laying keep dry and clean
  • Induction line in the docking process, please pay attention to male female connector pins order, alignment hole location and gently insert lock screw clockwise loops (counterclockwise)
  • Sensor cable laying area should be avoided by electrostatic interference
  • Induction line in laying area are not allowed to overlap or contact
  • Sensing line shall not be dirty water or other chemicals soak for a long time
  • Induction line should be close to the ground installation, the maximum contact leakage of liquid